  • Q What is the difference between safety light curtain and safety grating?

    A
    There is not much difference between safety grating and safety light curtain. Safety light curtain is also called safety grating, they are just two different names!
    The only difference is that their names are based on different references. Safety gratings are based on the fact that such products are in pairs 'grating rulers', so they are called safety gratings; safety light curtains are based on the working principles of relative gratings. A pair of gratings is a transmitter and a receiver. The transmitter emits a signal and the receiver receives the signal, thereby forming a light curtain with safety protection, so it is also called a safety light curtain. Therefore, it is also called a safety grating in the market, and it is also called a safety light curtain. It is also called a photoelectric protection device, a punch protector, an infrared protector, etc. There are many names.
  • Q What should I do if the safety light barrier fails and alarms?

    A You can check by following these steps:
    1. Check the light transmission: clean the dust and oil on the lens and confirm that there are no foreign objects blocking the light beam.
    2. Check the power supply and wiring: confirm that the power supply voltage is normal and that the wiring terminals are not loose or fallen off.
    3. Check the fault code: refer to the instruction manual and determine the specific cause (such as synchronization abnormality, signal interference, etc.) based on the indicator light or fault code.
    4. Reset operation: After troubleshooting, perform a manual reset to ensure normal recovery of the safety logic.
    If the problem still cannot be solved, please contact the manufacturer's technical support and do not disassemble the grating without permission.
  • Q Do safety light grids require regular maintenance? What are the maintenance points?

    A need. Regular maintenance is a key link to ensure the effectiveness of safety functions. It is recommended that:
    Daily cleaning:Wipe your lenses with a lint-free cloth and avoid using caustic cleaners.
    Functional test: Conduct a shading test before starting up every day or before each shift to confirm that the equipment can be shut down immediately after shading.
    Regular inspection:Check the status of wiring, fixing screws and indicator lights every quarter, and promptly replace or repair any abnormalities found.
    Record archive:Establish and maintain a ledger to facilitate traceability and auditing.
  • Q What precautions should be taken when installing safety gratings?

    A To ensure stable and reliable operation, special attention should be paid to the following during installation:
    Stable installation:The bracket should be firm to avoid vibration of the equipment during operation, which may cause the grating to shift.
    Light calibration:The transmitting end and receiving end must be strictly aligned to ensure that all light beams are transmitted normally.
    Safe distance:Calculate the minimum safety distance according to ISO 13855 standard to prevent the human body from failing to stop in time before entering the danger zone.
    Blind spot protection:Areas that cannot be covered by light gratings should be equipped with physical protection such as guardrails and safety doors.
  • Q How do I choose a suitable safety light barrier for my device?

    A When selecting, you can focus on the following 5 parameters:
    1. Protection height: should cover the longitudinal range of the dangerous area (such as the height of the mold opening).
    2. Optical axis spacing (resolution):
    Finger protection: commonly used 14mm / 20mm
    Palm/arm protection: commonly used 30mm/40mm
    3. Response time: For high-speed equipment, it is recommended to choose a fast response model of ≤10ms.
    4. Safety level: High-risk equipment should choose Type 4/PLe (ISO 13849-1) level products.
    5. Environmental adaptability: In scenes with heavy dust, strong vibration or electromagnetic interference, attention needs to be paid to the IP protection level and anti-interference performance.
Products are widely used in automobiles, new energy, photovoltaics, automation equipment, 3C industry, textile machinery, plastic machinery, packaging machinery, engineering machinery, petrochemical industry and other industries.

Product

Quick links

Join a global perspective

Get the latest industry white papers and technology updates.
© 2026 Shanghai Diqi Automation Equipment Co., Ltd. All rights reserved.  沪ICP备20012967号-1